Abstract

Secondary copper smelting is an important industrial source of unintentionally produced persistent organic pollutants (UPOPs) emissions. Herein, field study on industrial-scale plants was conducted to clarify the levels and profiles of polychlorinated biphenyls (PCBs), polychlorinated naphthalenes (PCNs) and chlorinated polycyclic aromatic hydrocarbons (> 3 rings, Cl-PAHs) from secondary copper smelting plants. The three UPOPs emission levels from the oxygen-enriched smelting furnace were higher than that from the anode furnace, which was attributed to the low-grade raw materials used. The toxic equivalent quantity concentrations of Cl-PAHs were 1.3–4.4 and 4.6–18.9 times higher than that of PCBs and PCNs, respectively. Thus, the emission control of Cl-PAHs in the secondary copper industry should be of concern. The chlorination degree of PCBs and PCNs was ~4 after the gas-cooling stage but was reduced to 1–2 in the stack outlet. This result indicated that the PCBs and PCNs congeners that were generated during the cooling stage were mainly higher-chlorinated. After purification by air pollution control devices (APCDs), the high-chlorinated congeners were removed simultaneously with the fly ash, whereas the low-chlorinated congeners may be regenerated and transferred into the stack gas due to possible memory effect within the APCDs.