Abstract

A method has been developed to analyse for malachite green (MG), leucomalachite green (LMG), crystal violet (CV) and leucocrystal violet (LCV) residues in salmon. Salmon samples were extracted with acetonitrile:McIIIvain pH 3 buffer (90:10 v/v), sample extracts were purified on a Bakerbond strong cation exchange solid phase extraction cartridge. Aliquots of the extracts were analysed by LC–MS/MS. The method was validated in salmon, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCα) was 0.17, 0.15, 0.35 and 0.17μgkg−1, respectively, for MG, LMG, CV and LCV and for the detection capability (CCβ) values of 0.30, 0.35, 0.80 and 0.32μgkg−1, respectively, were obtained. Fortifying salmon samples (n=6) in three separate assays, show the accuracy to be between 77 and 113% for MG, LMG, LCV and CV. The precision of the method, expressed as RSD values for the within-laboratory reproducibility, for MG, LMG and LCV at the three levels of fortification (1, 1.5 and 2.0μgkg−1), was less than 13%. For CV a more variable precision was obtained, with RSD values ranging between 20 and 25%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.