Abstract
We experienced unusual acoustic vibration in the operation of in-line array tubular heat exchangers named gas heater. This vibration mode was not one dimensional in the direction perpendicular to gas flow and could not be vanished by inserting baffle plates into the tube bundle along the gas flow. So we had to confirm acoustic vibration characteristics using 3-dimensional air flow scale model. Here, we report this test results about multi-stage gas heater and some countermeasure methods. Especially we discovered that unusual acoustic vibration mentioned above did not appeared in the case of some staggerd tube array having same heat transfer characteristics as in-line tube array.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.