Abstract

PurposeMeasurements of non-displaceable binding (VND) of positron emission tomography (PET) ligands are not often made in vivo in humans because they require ligands to displace binding to target receptors and there are few readily available, safe ones to use. A technique to measure VND for ligands for the 18-kDa translocator protein (TSPO) has recently been developed which compares the total volume of distribution (VT) before and after administration of the TSPO ligand XBD173. Here, we used XBD173 with an occupancy plot to quantify VND for two TSPO radiotracers, [18F]GE-180 and [11C]PBR28, in cohorts of people with multiple sclerosis (MS). Additionally, we compared plots of subjects carrying high (HAB) or mixed binding (MAB) affinity polymorphisms of TSPO to estimate VND without receptor blockade.ProceduresTwelve people with MS underwent baseline MRI and 90-min dynamic [18F]GE-180 PET or [11C]PBR28 PET (n = 6; three HAB, three MAB each). Arterial blood sampling was used to generate plasma input functions for the two-tissue compartment model. VND was calculated using two independent methods: the occupancy plot (by modelling the differences in signal post XBD173) and the polymorphism plot (by modelling the differences in signal across presence and absence of rs6971 genotypes).ResultsWhole brain VT (mean ± standard deviation) was 0.29 ± 0.17 ml/cm3 for [18F]GE-180 and 5.01 ± 1.88 ml/cm3 for [11C]PBR28. Using the occupancy and polymorphism plots respectively, VND for [18F]GE-180 was 0.11 ml/cm3 (95 % CI = 0.02, 0.16) and 0.20 ml/cm3 (0.16, 0.34), accounting for, on average, 55 % of VT in the whole brain. For [11C]PBR28, these values were 3.81 ml/cm3 (3.02, 4.21) and 3.49 ml/cm3 (1.38, 4.27), accounting for 67 % of average whole brain VT.ConclusionsAlthough VT for [18F]GE-180 is low, indicating low brain penetration, half the signal shown by MS subjects reflected specific TSPO binding. VT for [11C]PBR28 was higher and two thirds of the binding was non-specific. No brain ROIs were devoid of specific signal, further confirming that true reference tissue approaches are potentially problematic for estimating TSPO levels.

Highlights

  • volume of distribution (VT) for [18F]GE-180 is low, indicating low brain penetration, half the signal shown by multiple sclerosis (MS) subjects reflected specific translocator protein (TSPO) binding

  • No brain ROIs were devoid of specific signal, further confirming that true reference tissue approaches are potentially problematic for estimating TSPO levels

  • Several positron emission tomography (PET) ligands exist for the 18-kDa translocator protein (TSPO), which can be upregulated in the mitochondria of activated microglia when the central nervous system becomes inflamed

Read more

Summary

Conclusions

VT for [18F]GE-180 is low, indicating low brain penetration, half the signal shown by MS subjects reflected specific TSPO binding. VT for [11C]PBR28 was higher and two thirds of the binding was non-specific. No brain ROIs were devoid of specific signal, further confirming that true reference tissue approaches are potentially problematic for estimating TSPO levels

Introduction
Participants
Results
Discussion
Conclusion
Conflict of Interest