This paper presents experimental study on the response of a sustainable structure 3.65 x3.05x3.35 m, made with confined hollow concrete block masonry (CHCBM). The model was tested under quasi-static cyclic test to assess the response against seismic load and to determine the potential vulnerability. Based on test data, envelope curves and bilinear idealized curves were drawn according to both Magenes–Calvi and Elnashai methods. Different performance levels i.e. Immediate Occupancy (IO), Life Safety (LS) and Collapse Prevention (CP) were evaluated based on both methods. Damage pattern and force-deformation behavior of CHCBM building was compared with models of the similar configuration and loading conditions. Similarly values of Response modification factor (R), Displacement Ductility (µD) and Displacement amplification factor (Cd) were calculated and compared with the previously tested models and it confirmed that CHCBM building was ductile and structurally integrated under earthquake loading.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.