Abstract

The cone penetration test (CPT) has been used as a means of assessing the end bearing of driven piles in sand for many decades. This paper examines the predictive performance of four new such CPT-based methods recently included in the commentary of the 22nd edition of the American Petroleum Institute’s recommended practice for fixed offshore structures. It is demonstrated that the formulations given by one of these methods, referred to as UWA-05, provides better predictions than the three other CPT methods when tested against (i) an existing database of base-capacity measurements, (ii) results from a new series of load tests on small-diameter piles, and (iii) base capacities measured in two recently conducted load tests on 1.5 m diameter pipe piles. It is shown that the UWA-05 has better predictive performance (and hence reliability) as it accounts explicitly for the effects of partial plugging during pipe–pile installation and for variations in CPT resistance in the vicinity of the pile tip.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.