Abstract

AbstractIn this paper, a novel polishing method using magnetorheological (MR) fluid is presented in order to improve conductor‐surface roughness and achieve high‐frequency performance of the electroplated three‐dimensional (3D) CPW, where the MR fluid is utilized to efficiently polish uneven and imperfect conductor surfaces resulting from the widely used MEMS process. For the purpose of comparison, two 50Ω CPW lines on glass substrate are fabricated in order to validate the performance of the proposed polishing scheme. From the measurement, the polished CPW lines using the MR fluid show much lower attenuation constants up to a maximum of 0.3–0.54 dB/cm than unpolished CPW lines, according to the geometries used. Thus, it is clear that the proposed MR fluid‐based polishing scheme is very effective when used to smooth 3D high‐frequency structures and can dramatically improve conductor‐loss characteristics. © 2004 Wiley Periodicals, Inc. Microwave Opt Technol Lett 42: 405–407, 2004; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.20318

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.