Abstract

Incipient faults on blade load sensors can impede the sound performance of a wind turbine, leading to increasing loads over time and severe blade degradation. As such, knowledge of the blade load sensors’ health is essential for ensuring effective load reduction by means of individual pitch control. This paper presents a condition monitoring strategy for the blade load sensors based on estimation of the loads acting on the rotor blades in the full-load region. Fault detection is achieved via appropriate residual generators, the statistical properties of which are used to design change detectors robust against measurement noise and wind field stochasticity. Specifically, a Generalized Likelihood Ratio Test for the t-LocationScale distribution is developed for ensuring robust detection of sensor blade faults. The proposed method is evaluated in a high-fidelity simulator under non-uniform wind scenarios. The simulation results show that detection of multiplicative faults on the blade load sensors is achieved even in absence of knowledge of the local wind speed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.