Abstract

In this study, we measured counter-current flow limitation (CCFL) characteristics in an inverted U-tube (18.4 mm diameter and 1.0 m straight-part length) simulating steam generator (SG) U-tubes under conditions of steam condensation at pressures of 0.1–0.14 MPa. Differential pressure ΔP between the top of the inverted U-tube and the lower tank was measured, and the flow patterns wave estimated by comparing the waveforms of ΔP with those in air–water experiments. As a result, we classified the flow patterns under CCFL conditions into CCFL-P, CCFL-L and CCFL-T. The falling water flow rate under CCFL conditions slightly increased as the pressure increased and the cooling water temperature decreased (subcooling of cooling water increased). In the case of CCFL-L, CCFL characteristics in the inverted U-tube were between those in air–water and saturated steam–water experiments at 0.1 MPa. Furthermore, we derived a Wallis type CCFL correlation and its uncertainty from CCFL data, including previously measured data, i.e., J*1/2G + 0.88JL*1/2 = 0.76 ± 0.05.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.