Abstract

Concurrent calorimetric and interferometric studies have been conducted to investigate the effect that reduction of the base-plate dimensions has on the steady-state performance of the rate of natural convection heat transfer from miniaturized horizontal single plate-fin systems and plate-fin arrays. The effect was studied through comparison of the present results with those of earlier relevant calorimetric, interferometric, or numerical studies. Results shown that a reduction of the base-plate area by 74% increased natural convection coefficient by 1.5 times to 26.0 W m−2 K−1 for single fin systems and by 1.8 times to 18 W m−2 K−1 for fin arrays in the range of the base-plate temperature excess of 20–50°C. A simple correlation for the Nusselt number of miniaturized horizontal plate-fin arrays is proposed in the range of Rayleigh number divided by the number of fins to the 2.7 power from 2 × 10 to 5 × 105.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call