Abstract

This paper carried out a series of tests on concrete-filled double skin steel tubes (CFDST) columns under long-term sustained loading condition. The test process included two stages, i.e. long-term service test and ultimate strength test. Numerical models on analysis of the CFDST column under long-term sustained loading were presented. A comparison of results calculated using these models showed generally good agreement with the test results. Additionally, a detailed analysis was performed to analyse the long-term behaviour of CFDST columns. Finally, simplified formula for calculating the ultimate strength of CFDST columns subjected to long-term sustained loading was proposed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.