Abstract

Background and objectiveThere is a growing body of evidence that the equations used to estimate the glomerular filtration rate (GFR) are not suitable in critically ill patients, a population whose GFR fluctuates continuously. Glomerular filtration is usually estimated by measuring urine creatinine clearance (CrCl) at various time points. The aim of our study was to evaluate the performance of the most widely used GFR calculators in the subpopulation of critically ill patients admitted for severe trauma, and to compare the results against determinations of CrCl in urine collected over a 4-hour period (4h-CrCl). Material and methodsObservational study in patients hospitalized for severe trauma. We measured the 4h-CrCl and estimated GFR using the Cockcroft-Gault, modified Jelliffe, MDRD, t-MDRD, and CKD-EPI equations, adjusting the results for body surface area (BSA) (ml/min/1.73m2). Data were analysed using R version 4.0.4. ResultsA total of 85 patients were included. Median age was 51years, and 68 were men (78.82%). The mean BSA-adjusted 4h-CrCl (4h-ClCr/1.73m2) was 84.5ml/min/1.73m2. We found that GFR estimated using the t-MDRD equation correlated significantly with 4h-CrCl/1.73m2. The Cockcroft-Gault equation correlated significantly with 4h-CrCl/1.73m2 when GFR was greater than 130ml/min/m2. ConclusionsIn ICU patients, glomerular filtration can be reliably estimated by determining urine CrCl, but GFR calculators are not accurate in this population.