Abstract

After excluding 4 patients with an anesthesia duration of < 2 hours, data from 34 patients (1163 sets of tracheal and esophageal temperatures) were analyzed. Concordance correlation coefficient was 0.78. The overall mean bias (95% limits of agreement) between the tracheal and esophageal temperatures was -0.16°C (-0.65°C to 0.34°C). The percentage of temperature differences within ± 0.25°C was 73.5% ± 32.3, with a median of 89.4% [0,100]. The linear mixed-effects model revealed that the estimated intercept was 0.17°C with a 95% confidence interval (CI) of 0.13°C to 0.22°C. The duration of anesthesia and the number of temperature measurements were associated with higher concordance between the tracheal and esophageal temperatures in univariate analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.