Abstract

Water electrolysis is currently a major technique to produce clean hydrogen, which is regarded as a promising and sustainable energy carrier. The efficiency of water electrolysis is highly dependent on the oxygen evolution reaction (OER) on the anode. The evaluation of an OER electrocatalyst is frequently carried out on a three-electrode system in a container of electrolyte. Herein, we found that the electrode positions in the electrolyte container could significantly affect the data acquisition of OER performance. After a detailed investigation, we reveal that the difference of the OER activity of an electrocatalyst at a different position is originated from their different iRu drop and the gas diffusion resistance. For the first time, this work evokes concerns on the accurate evaluation of electrocatalysts regarding the electrode position. For fair comparisons and reliable results, it is strongly suggested to keep the electrode position unchanged in the electrochemical measurements. In addition, the establishment of a standard electrolyzer setup for electrocatalysis evaluation in the electrochemical community is also called for.