Abstract

Here, we have developed conceptual designs of two petawatt-class pulsed-power accelerators: Z 300 and Z 800. The designs are based on an accelerator architecture that is founded on two concepts: single-stage electrical-pulse compression and impedance matching [Phys. Rev. ST Accel. Beams 10, 030401 (2007)]. The prime power source of each machine consists of 90 linear-transformer-driver (LTD) modules. Each module comprises LTD cavities connected electrically in series, each of which is powered by 5-GW LTD bricks connected electrically in parallel. (A brick comprises a single switch and two capacitors in series.) Six water-insulated radial-transmission-line impedance transformers transport the power generated by the modules to a six-level vacuum-insulator stack. The stack serves as the accelerator’s water-vacuum interface. The stack is connected to six conical outer magnetically insulated vacuum transmission lines (MITLs), which are joined in parallel at a 10-cm radius by a triple-post-hole vacuum convolute. The convolute sums the electrical currents at the outputs of the six outer MITLs, and delivers the combined current to a single short inner MITL. The inner MITL transmits the combined current to the accelerator’s physics-package load. Z 300 is 35 m in diameter and stores 48 MJ of electrical energy in its LTD capacitors. The acceleratormore » generates 320 TW of electrical power at the output of the LTD system, and delivers 48 MA in 154 ns to a magnetized-liner inertial-fusion (MagLIF) target [Phys. Plasmas 17, 056303 (2010)]. The peak electrical power at the MagLIF target is 870 TW, which is the highest power throughout the accelerator. Power amplification is accomplished by the centrally located vacuum section, which serves as an intermediate inductive-energy-storage device. The principal goal of Z 300 is to achieve thermonuclear ignition; i.e., a fusion yield that exceeds the energy transmitted by the accelerator to the liner. 2D magnetohydrodynamic (MHD) simulations suggest Z 300 will deliver 4.3 MJ to the liner, and achieve a yield on the order of 18 MJ. Z 800 is 52 m in diameter and stores 130 MJ. This accelerator generates 890 TW at the output of its LTD system, and delivers 65 MA in 113 ns to a MagLIF target. The peak electrical power at the MagLIF liner is 2500 TW. The principal goal of Z 800 is to achieve high-yield thermonuclear fusion; i.e., a yield that exceeds the energy initially stored by the accelerator’s capacitors. 2D MHD simulations suggest Z 800 will deliver 8.0 MJ to the liner, and achieve a yield on the order of 440 MJ. Z 300 and Z 800, or variations of these accelerators, will allow the international high-energy-density-physics community to conduct advanced inertial-confinement-fusion, radiation-physics, material-physics, and laboratory-astrophysics experiments over heretofore-inaccessible parameter regimes.« less

Highlights

  • Over the past five decades, more than one hundred major pulsed-power accelerators have been developed by the international scientific community

  • The ZR Facility conducts approximately 150 accelerator shots each year. These drive a wide variety of high-energydensity-physics (HEDP) experiments in support of the U.S National Nuclear Security Administration’s Stockpile Stewardship Program

  • We have developed two circuit models of Z 300: one assumes this machine is coupled to a magnetized-liner inertial-fusion (MagLIF) target [60,61,62,63,64,65,66,67,68,69]; the other, a dynamic hohlraum [70,71,72,73,74,75]

Read more

Summary

INTRODUCTION

Over the past five decades, more than one hundred major pulsed-power accelerators have been developed by the international scientific community. To the extent possible, the transmission lines that transport the power pulse from the prime-power source to the load be impedance matched throughout This approach minimizes reflections within the accelerator and maximizes the efficiency at which electrical energy and power are delivered to the load. We describe conceptual designs of two such accelerators: Z 300 and Z 800 [41] These machines are petawatt-class accelerators that generate a 100-ns electrical power pulse at twice the energy efficiency of ZR. It is clear that a complete understanding of the performance of an accelerator that generates on the order of a petawatt of peak electrical power in a 100-ns pulse requires detailed and accurate numerical simulations.

CONCEPTUAL DESIGN OF Z 300
CIRCUIT MODELS OF THE MAGLIF AND DYNAMIC-HOHLRAUM LOADS ASSUMED FOR Z 300
RESULTS
CONCEPTUAL DESIGN OF Z 800
CIRCUIT MODELS OF Z 800
VIII. CIRCUIT MODELS OF THE MAGLIF AND DYNAMIC-HOHLRAUM LOADS ASSUMED FOR Z 800
ACCELERATOR ENERGY EFFICIENCY
ACCELERATOR-DESIGN CONSIDERATIONS
SUGGESTIONS FOR FUTURE WORK
Zload þ
MITLs ðLcon þ
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.