Abstract

After the completion of the third experimental campaign in 2018, actively cooled high heat flux divertors (10 pcs.) will be implemented within the stellarator fusion experiment Wendelstein 7-X (W7-X). A cryo vacuum pump will be installed in the plasma vessel behind the divertor. These pumps will be cooled with super critical helium at 3.9 K and liquid nitrogen at 80 K. A multichannel transfer line connects the helium refrigerator with a valve box located below the W7-X cryostat. From there, 10 parallel transfer lines run to the cryo pumps inside the plasma vessel. The lay out and the hydraulic design of the distribution system are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.