Abstract

Particulate matter (PM) is increasingly affecting the social-economic development of countries. An increase in PM2.5 concentration increases susceptibility to cardiovascular and respiratory diseases and cancer. Tire wear particles (TWP) contribute to airborne PM. In the present work, we investigated the variation in the concentration of TWP of <2.5 μm in aerodynamic diameter (TWP2.5) in an indoor parking garage depending on the sampling sites. PM2.5 samples were collected at four sites in an indoor parking garage of a college campus: the entrance of the parking garage (Ent), the second floor toward the third floor (2F), the front of the parking zone on the second floor (2FP), and the third floor toward the fourth floor (3F). Each PM2.5 sampling was performed for 4 days during the fall season. The PM2.5 concentrations at the 2F and 2FP were similar to the outside PM2.5 concentrations, whereas those at the Ent and 3F were higher than the outside PM2.5 concentrations. The TWP2.5 concentrations in the indoor parking garage were 0.61–0.73 μg/m3. The differences in the TWP2.5 concentrations depending on the sampling sites were due to the differences in traffic volumes. The TWP2.5 concentration at the 2FP was higher than those at the other sampling sites owing to air stagnation and TWPs produced by the high friction when parking and exiting a car in the parking zone. The contributions of TWP2.5 to the PM2.5 concentrations were 3.9–11.7%, in the order of 2FP ≫ Ent > 3F > 2F. A good air ventilation system can be recommended to reduce TWP2.5 concentrations in indoor parking garages.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call