Abstract

There is mounting evidence for the waterborne transmission of diarrhea caused by rotaviruses. As a result, proper techniques are required for their recovery from samples of incriminated water. The combined efficiency of the talc-Celite technique and polyethylene glycol 6000 hydroextraction was, therefore, tested for this purpose, using Simian rotavirus SA-11 and MA-104 cells. Conditioning of the dechlorinated tap water samples was carried out by pH adjustment to 6.0 and the addition of Earle balanced salt solution to a final concentration of 1:100. Passage of a 1-liter volume of such a conditioned sample through a layer containing a mixture of talc (300 mg) and Celite 503 (100 mg) led to the adsorption of nearly 93% of the added SA-11 plaque-forming units. For the recovery of the layer-adsorbed virus, 3% beef extract and 1x tryptose phosphate broth were found to be superior to a variety of other eluents tested. When we tested 100-liter sample volumes, layers containing 1.2 g of talc and 0.4 g of Celite were employed. Virus elution was carried out with 100 ml of tryptose phosphate broth. The eluate was concentrated 10-fold by overnight (4 degrees C) hydroextraction with polyethylene glycol. With a total input virus of 7.0 x 10(5) and 1.4 x 10(2) plaque-forming units, the recoveries were about 71 and 59%, respectively.