Abstract
Airborne concentrations of diazinon were measured in rooms for 21 days after crack and crevice application. Residue levels were largest in treated rooms (38 micrograms/m3) after application, followed by adjacent (1 microgram/m3) and upper and lower rooms (ca. 0.4 microgram/m3). Low levels of diazinon were detected in all rooms 21 days after application. Small amounts of diazinon (corrected to an 8 min application period) were detected on respirator pads (2.6 microgram) and waist pads (2.3 microgram) worn by the applicator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of environmental science and health. Part. B, Pesticides, food contaminants, and agricultural wastes
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.