Abstract
A program to develop models for the enable computer calculation of conductor temperature rise versus time in trailing cables has been initiated. To date, a common model equation has been developed and parameters determined for two round trailing cables typically used on continuous miners, type G-GC, sizes 2/0 AWG and 4/0 AWG, rated 90 degrees C. The resulting cable models have been tentatively confirmed in laboratory trials using repetitive four-level constant-current cycles and triangular currents in which the peak current varied on succeeding cycles. Model refinement and additional laboratory trials are projected using randomly varying current, simulating actual current conditions in mine trailing cables. >
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.