Abstract

Purpose: Arterial waveform parameters (WPs) are commonly used to monitor and diagnose systemic diseases. Color Doppler Imaging (CDI) is a consolidated technique to measure blood velocity profile in some of the major ocular vessels. This study proposes a computer-aided manipulation process of ophthalmic artery (OA) CDI images to classify and quantify WPs that might be significant in the assessment of glaucoma.Methods: Fifty CDI images acquired by four different operators on nine healthy individuals and 38 CDI images of 38 open-angle glaucoma (OAG) patients were considered. An ad-hoc semi-automated image processing code was implemented to detect the digitalized OA velocity waveform and to extract the WPs. Concordance correlation coefficient (CCC), two-sample t-test and Pearson’s correlation coefficient were used to test for similarities, differences and associations among variables.Results: The OA-CDI images manipulation proposed showed a higher concordance between measured peak systolic velocity (PSV) data and extracted PSV data (0.80≤CCC≤0.98) than on end diastolic velocity (EDV) (0.45≤CCC≤0.63) and resistive index (RI) (0.30≤CCC≤0.58) data. In OAG patients, EDV, RI, subendocardial viability ratio (SEVR), period (T), area ratio (f) and normalized distance between ascending and descending limb (DAD/T) were found statistically correlated to at least one of the following factors: gender, age, ocular medications and year of diagnosis. When compared to healthy individuals, OAG patients OA-CDI profiles showed statistically higher values of f (p < 0.001) and DAD/T (p = 0.002) (p-values corrected by age and gender).Conclusion: The proposed computer-aided manipulation of OA-CDI images allowed to identify DAD/T as a novel WP that vary significantly among healthy individuals and OAG patients, and among female and male OAG patients. Future studies on longitudinal OAG data are suggested to investigate the potential of DAD/T to predict severity and progression of the disease.

Highlights

  • Ophthalmic disease encompasses many risk factors and physiological pathways, including those of the ocular vasculature

  • The ophthalmic artery (OA)-Color Doppler imaging (CDI) images manipulation proposed showed a higher concordance between measured peak systolic velocity (PSV) data and extracted PSV data (0.80≤correlation coefficient (CCC)≤0.98) than on end diastolic velocity (EDV) (0.45≤CCC≤0.63) and resistive index (RI) (0.30≤CCC≤0.58) data

  • When considering all individuals included in the study, i.e., healthy individuals and glaucoma patients, the analysis showed an excellent concordance on PSV (CCC = 0.85; 95%CI 0.77-0.93), a good concordance on EDV (CCC = 0.63; 95%CI: 0.49-0.78) and a fair concordance on RI (CCC = 0.33; 95% Confidence Interval (95% CI): 0.14-0.52)

Read more

Summary

Introduction

Ophthalmic disease encompasses many risk factors and physiological pathways, including those of the ocular vasculature. Vascular deficits are more prone in certain groups such as those of African descent.[11] Geometric and hemodynamic features of the ocular vasculature can be visualized and measured using various techniques, such as fundus imaging, optical coherence tomography (OCT), Heidelberg retinal flowmetry (HRF), confocal scanning laser flowmetry, cannon laser blood flowmeter, retinal angiography, and Color Doppler imaging (CDI). CDI is a consolidated technique to measure blood velocity profile in some of the major ocular vessels, including the ophthalmic artery (OA), the central retinal artery (CRA), the posterior ciliary arteries (PCAs), as well as the central retinal vein (CRV). CDI studies have shown significant blood velocity derangements in the OA, CRA, and PCAs in association with diabetic retinopathy,[13] glaucoma,[14,15,16,17] and they have been utilized to estimate the intracranial pressure (ICP) noninvasively.[18]

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call