Abstract

BackgroundAlthough treatments have been proposed for calcinosis cutis (CC) in patients with systemic sclerosis (SSc), a standardized and validated method for CC burden quantification is necessary to enable valid clinical trials. We tested the hypothesis that computer vision applied to dual-energy computed tomography (DECT) finger images is a useful approach for precise and accurate CC quantification in SSc patients.MethodsDe-identified 2-dimensional (2D) DECT images from SSc patients with clinically evident lesser finger CC lesions were obtained. An expert musculoskeletal radiologist confirmed accurate manual segmentation (subtraction) of the phalanges for each image as a gold standard, and a U-Net Convolutional Neural Network (CNN) computer vision model for segmentation of healthy phalanges was developed and tested. A validation study was performed in an independent dataset whereby two independent radiologists manually measured the longest length and perpendicular short axis of each lesion and then calculated an estimated area by assuming the lesion was elliptical using the formula long axis/2 × short axis/2 × π, and a computer scientist used a region growing technique to calculate the area of CC lesions. Spearman’s correlation coefficient, Lin’s concordance correlation coefficient with 95% confidence intervals (CI), and a Bland-Altman plot (Stata V 15.1, College Station, TX) were used to test for equivalence between the radiologists’ and the CNN algorithm-generated area estimates.ResultsForty de-identified 2D DECT images from SSc patients with clinically evident finger CC lesions were obtained and divided into training (N = 30 with image rotation × 3 to expand the set to N = 120) and test sets (N = 10). In the training set, five hundred epochs (iterations) were required to train the CNN algorithm to segment phalanges from adjacent CC, and accurate segmentation was evaluated using the ten held-out images. To test model performance, CC lesional area estimates calculated by two independent radiologists and a computer scientist were compared (radiologist 1 vs. radiologist 2 and radiologist 1 vs. computer vision approach) using an independent test dataset comprised of 31 images (8 index finger and 23 other fingers). For the two radiologists’, and the radiologist vs. computer vision measurements, Spearman’s rho was 0.91 and 0.94, respectively, both p < 0.0001; Lin’s concordance correlation coefficient was 0.91 (95% CI 0.85–0.98, p < 0.001) and 0.95 (95% CI 0.91–0.99, p < 0.001); and Bland-Altman plots demonstrated a mean difference between radiologist vs. radiologist, and radiologist vs. computer vision area estimates of − 0.5 mm2 (95% limits of agreement − 10.0–9.0 mm2) and 1.7 mm2 (95% limits of agreement − 6.0–9.5 mm2, respectively.ConclusionsWe demonstrate that CNN quantification has a high degree of correlation with expert radiologist measurement of finger CC area measurements. Future work will include segmentation of 3-dimensional (3D) images for volumetric and density quantification, as well as validation in larger, independent cohorts.

Highlights

  • Treatments have been proposed for calcinosis cutis (CC) in patients with systemic sclerosis (SSc), a standardized and validated method for CC burden quantification is necessary to enable valid clinical trials

  • CC lesional area estimates calculated by two independent radiologists and a computer scientist were compared using an independent test dataset comprised of 31 images (8 index finger and 23 other fingers)

  • For the two radiologists’, and the radiologist vs. computer vision measurements, Spearman’s rho was 0.91 and 0.94, respectively, both p < 0.0001; Lin’s concordance correlation coefficient was 0.91 and 0.95; and Bland-Altman plots demonstrated a mean difference between radiologist vs. radiologist, and radiologist vs. computer vision area estimates of − 0.5 mm2 (95% limits of agreement − 10.0–9.0 mm2) and 1.7 mm2

Read more

Summary

Introduction

Treatments have been proposed for calcinosis cutis (CC) in patients with systemic sclerosis (SSc), a standardized and validated method for CC burden quantification is necessary to enable valid clinical trials. We tested the hypothesis that computer vision applied to dual-energy computed tomography (DECT) finger images is a useful approach for precise and accurate CC quantification in SSc patients. Calcinosis cutis (CC) is defined as the deposition of insoluble calcium salts within the skin and subcutaneous tissues [1]. Dystrophic calcification from local tissue injury is the most common subtype and is associated with autoimmune disorders including systemic sclerosis (SSc) and juvenile dermatomyositis (JDM). Valid clinical trial design to test the safety and efficacy of proposed systemic treatments requires a feasible, precise, and reproducible method for CC burden quantification

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.