Abstract

Design data are given for multisection double-plane step transformers between X- (8.2-12.4 GHz), Ku- (12.4.-18 GHz), K- (18-26.5 GHz), and Ka- (26.5-40 GHz) band waveguides. The calculations, based on a field expansion into orthogonal eigenmodes, take into account the influence of higher order modes. For frequency ranges other than the bands given, simple scaling formulas based on the optimized data yield transformer designs with sufficiently low VSWR. Optimum short transformers are possible if the total transformer length is included within the error function to be optimized. Measurements agree with theory.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.