Abstract

A computer program to calculate the strip temperature heated in the continuous annealing furnace was developed, using the zone method for radiative heat transfer analysis with the measured gas temperature in the furnace. Using the FE operator, the present study considered the effects of soot and transient species in addition to the H2O-CO2 gas mixture on the gas radiative heat transfer. The predicted strip temperature distribution for FE = 1.05 represented well the measured data. The maximum difference in the heat flux transfered to the strip from the combustion gas for FE = 1.0 (without soot and transient species gas radiation) and 1.05 (with soot and transient species gas radiation) was about 15 percent. The present study also investigated the effects of line speed and thickness variations on the strip temperature, establishing the bases for the on-line computer model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.