Abstract
The aim of the present study was to evaluate the accuracy of 3-dimensionally (3D) printed patient-specific guides (PSGs) to direct the passage of inlet and outlet needles into the superior joint spaces of the temporomandibular joint (TMJ) in preparation for arthrocentesis. The present study included 10 patients with 14 TMJs with anterior disc displacement with reduction. A 3D PSG was designed for each patient to lead the inlet and outlet needles into the superior joint space of the TMJ. The PSGs were implemented, and their accuracy for guiding the needles into the superior joint space was assessed. Both arthroscopic verification and clinical evaluation revealed that direct access to all the predetermined anatomic locations inside the TMJs had been obtained, except for 1 case, during which the patient had failed to maintain the maximum mouth opening during computed tomography scanning. The virtual computer-initiated PSGs were beneficial for directing the passage of the needles into the superior joint space.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.