Abstract
Retort sterilization is critical in the food industry. However, retorts are not smart enough to fully monitor and calculate their energy usage to reduce their carbon emissions. In this project, sensors and network equipment were installed in a retort, and a PC-based system was used to process the collected data. To monitor the sterilization status and energy consumption, we added flow sensors and electricity meters and built a visual identification system. Carbon emissions were calculated, and energy conservation and carbon emission reduction strategies were explored. According to the monitoring data, the electricity consumption of the air compressor, boiler, and natural gas combustion accounted for 80 % of the total carbon emissions. If the equipment cannot be changed, the cooling water system can be stopped in noncooling stages to conserve energy. This strategy reduced the energy consumption of the cooling system by 70 % and was the most effective strategy for this project.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.