Abstract

The purpose of the study was to evaluate feasibility and safety of CT-fluoroscopy in the drainage of pericardial effusion in cases not accessible by sonography. Eleven drainages were performed in Seldinger-technique under CT-fluoroscopy on eight patients suffering from pericardial effusion. The inclusion criterion was a sonographically proved pericardial effusion not drainable under sonographic surveillance. In seven procedures the catheter was positioned using a medial, in four procedures a lateral approach from the apex was chosen. All catheters could be placed successfully (11/11) in the pericardial effusion and allowed for draining of the effusion in 10 of 11 cases. One epicardial laceration necessitated a surgical approach. The elapsed total procedure time for the drainage was on average 18:23 +/- 8:58 minutes. Visual surveillance by CT-fluoroscopy is a feasible method in the drainage of pericardial effusions even in cases not accessible by ultrasound.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.