Abstract

Introduction: Using computed tomography (CT) and treatment planning systems (TPS) in radiotherapy, due to the difference in photon beam energy on CT and linear accelerator, it is necessary to convert Hounsfield units (HU) to relative electron density (RED) values. The aim of this dosimetric study was to determine whether there is a significant effect of potential in the CT tube, field of view size (FOV), and phantom dimensions on the CT conversion curve CT-RED. The second aim is whether there are significant differences between the CT-RED obtained by the Computerized Imaging Reference Systems (CIRS) Thorax 002LFC phantom and the “reference” curve in the TPS, obtained by the CIRS 062M pelvis phantom, at the same CT conditions.Methods: Heterogeneous CIRS 062M and CIRS Thorax 002LFC phantoms were used, which anatomically and dimensionally represent the human pelvis, head, and thorax, with a set of known RED inserts. They were scanned on a CT LightSpeed GE simulator and obtained CT-RED.Results: The high voltage in the CT tube had a significant effect on the HU (t = 10.72, p < 0.001) for RED values >1.1, while FOV as a parameter did not show statistical significance for the 062M pelvis phantom. Comparing the slopes (062M pelvis and head) of the CT-RED for RED ≥ 1.1, the obtained value is t = 1.404 (p = 0.163). In the case of a 062M pelvis and a 002LFC phantom, we have seen a difference in RED values (for the same HU value) of 5 % in the RED region ≥ 1.1 (bone).Conclusion: Patients should be imaged on a CT simulator only at the potential of the CT tube on which the conversion curve was recorded. The influence of the FOV and scanned phantom dimensions is not statistically significant on the appearance of the calibration curve (RED ≥ 1.1).

Highlights

  • Using computed tomography (CT) and treatment planning systems (TPS) in radiotherapy, due to the difference in photon beam energy on CT and linear accelerator, it is necessary to convert Hounsfield units (HU) to relative electron density (RED) values

  • The shape of the calculated isodose distribution in the patient depends on the calculation algorithm and the data from the CT and the medical linear accelerator (LINAC) entered into the TPS [2]

  • Photon beam attenuation coefficient of one element depends on the relative electron density (RED), atomic number (Z), and quality of the photon beam obtained from the CT scanner [3]

Read more

Summary

Introduction

Using computed tomography (CT) and treatment planning systems (TPS) in radiotherapy, due to the difference in photon beam energy on CT and linear accelerator, it is necessary to convert Hounsfield units (HU) to relative electron density (RED) values. The aim of this dosimetric study was to determine whether there is a significant effect of potential in the CT tube, field of view size (FOV), and phantom dimensions on the CT conversion curve CT-RED. Photon beam attenuation coefficient of one element depends on the relative electron density (RED), atomic number (Z), and quality (energy) of the photon beam obtained from the CT scanner [3]

Methods
Results
Conclusion