Abstract

Complications of peribulbar anaesthesia include retrobulbar haemorrhage, globe perforation and brainstem anaesthesia. Therefore, this study took measurements relating the proximity of medial canthus to the optic nerve and also the safe angle between orbit and globe using 200 multiplanar reconstructed computed tomography (CT) images of the orbit. The principal results show that in 1.5% of the sample, the optic nerve is within 20 mm of the medial canthus, with a minimum distance of 15 mm. One% have a safe angle of 10 degrees or less between bone and globe. None of the demographic data, nor axial length were predictive of these results. We have shown that there are a minority of patients with unusual orbital anatomy. This places them at a theoretical higher risk of complications. These cases are not currently predicted by measured data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.