Abstract

In the past, many researchers have studied the correlation between quantitative parameters of computed tomography (CT) and parameters of pulmonary function test (PFT) in patients with chronic obstructive pulmonary disease (COPD) with good results. Most of these studies have focused on the whole-lung level. In this study, we analyzed the biphasic CT lung volume parameters and the percentage of emphysema volume in different lobes of the lungs of patients with different grades of COPD and assessed their relationship with different lung function indices. We retrospectively collected patients who underwent PFTs at The First Affiliated Hospital of Guangzhou Medical University from 1 July 2019 to 27 January 2020, and underwent chest respiratory dual-phase CT scans within 1 week, including 112 non-COPD patients and 297 COPD patients. We quantified the biphasic CT lung volume parameters and the percentage of emphysema volume in different lobes using a pulmonary image analysis tool. One-way analysis of variance (ANOVA) and Kruskal-Wallis H method were used to compare the quantitative CT parameters of each lung lobe in different groups. The correlation between quantitative CT parameters of different lung lobes and lung function indices was assessed using multiple linear regression. Among the 3 biphasic CT lung volume parameters, only volume change/inspiratory lung volume (∆LV/LVin) in the non-COPD control, mildly to moderately severe, and severe to extremely severe groups had statistical differences in each lobe level (all P<0.05). Correlation was significant between LVin and different lung function indices and between low attenuation areas percent below the threshold of -950 in the inspiratory phase [low attenuation area below -950 in the inspiratory phase (%LAA-950in)] and lung function indices in the left lower lobe (all P<0.05). There was statistically significant correlation between expiratory lung volume and ∆LV/LVin and lung function indices in the right lower lung (all P≤0.001). In the remaining lobes, LVin, expiratory lung volume, ∆LV/LVin, and %LAA-950in correlated with only some of the lung function indices. The percentage of emphysema volume did not differ between lobes in the non-COPD control and severe to extremely severe COPD populations. LVin and %LAA-950in in the left upper lobe, expiratory lung volume and ∆LV/LVin in the right lower lobe were more reflective of the changes in lung function indices of the patients, whereas the correlation of the 3 biphasic CT lung volume parameters and the percentage of emphysema volume in the upper lobes of both lungs and the right middle lung with lung function indices was unclear.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call