Abstract

Although the high-attenuating crescent (HAC) sign can indicate aortic aneurysm (AA) impending rupture, the relation of its computed tomography (CT) value to the aneurysmal status remains unclear. This study compared the HAC sign CT-attenuation values among rupture, impending rupture, and non-rupture AA cases.Methods and Results:This included 76 patients (mean age: 77.0 years) diagnosed with HAC sign-associated AA between January 2005 and July 2015. The CT-attenuation values of the HAC sign (H) and aortic lumen (A) using region-of-interest methodology were measured and the H/A ratio was calculated. The study classified patients into the rupture group (R-G, n=36), impending rupture group (IR-G, n=16), and non-rupture group (NR-G, n=24); the H and the H/A ratio were compared among them. Additionally, the H and the H/A ratio cut-offs between the IR-G and NR-G groups were evaluated. The H and the H/A ratio were significantly higher in the R-G and IR-G than in the NR-G (both P<0.001); the H/A ratio was significantly higher in the R-G than in the IR-G (P=0.038). The optimal cut-off for H between the IR-G and NR-G was 50.3 Hounsfield units (area under the curve [AUC]=0.875; sensitivity=87.5%; specificity=87.5%), and that for the H/A ratio was 1.3 (AUC=0.909; sensitivity=91.7%; specificity=87.5%). Among patients with AA, the H and the H/A ratio were significantly higher in cases of rupture and impending rupture than in those of non-rupture.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call