Abstract

A computational and experimental investigation of three-dimensional mean flow field resulting due to the free stream turbulence on film cooling performance has been reported in this present paper. A row of square jet with L/D ratio of 2.5 as a reference case has been employed. The free stream turbulence intensity of 8% and the blowing ratio of 0.5 are investigated to check the impact of jet velocity on the cooling performance. The objective of the present work was to carry out a detailed investigation of the mean flow field and flow structure. Numerical simulations were performed using the commercial code FLUENT 6.2.16 based on the finite volume method with two different models, namely, k-ε, RSM models. The results of the preliminary computational analysis show that the flow field produced by the free stream provides a serious impact on the film cooling performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.