Abstract

This paper presents the results of computational kinetic modelling of the removal of nitrogen oxides (NOx) from flue gases by selective non-catalytic reduction (SNCR) process using urea as a reducing agent. CHEMKIN and SENKIN computer codes were used with latest reaction mechanism parameters for simulated conditions in an isothermal plug flow reactor. Flue gas initial conditions were simulated as 70 litres/min propane containing 500 ppm background NOx. A range of molar ratios was studied at optimum temperature. Carbon monoxide and hydrogen were investigated as potential enhancers to lower the temperature window. The modelling results suggested that the optimum temperature for peak reduction was around 1075C with optimum molar ratios of 1.5. Hydrogen was found to be an efficient enhancer. The optimum residence time was found to be about 80 milliseconds.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.