Abstract

In the calculation of wind effects on civil constructions, the pressure coefficients, which are usually obtained from specific standards or by tests of reduced models in wind tunnels, are essential, and these coefficients are commonly established from solid and undeformable models. For greenhouses covered with plastic film, due to the flexibility of this material, there are instantaneous modifications to the shape of the construction by the action of the wind. The aim of this study was to investigate the distribution of pressure coefficients on arched roof greenhouses displaced by the wind action transverse to the ridge. To achieve this goal, computational fluid dynamics (CFD) models were used to obtain the pressure coefficients in greenhouses with ratios between height and span of 0.3 and 0.6. The change in the shape of the greenhouse due to the displacements imposed by the wind showed that there were no relevant variations in the pressure coefficients of the wall zones. However, the effects of shape displacement were very significant along the extension of the arch of the roof, with a large reduction in the pressure coefficients mainly in the vicinity of the ridge.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.