Abstract
A computational model for RO system design and performance prediction was developed in this study. The model was developed to estimate the performance parameters of RO in a multiple membrane elements pressure vessel. For simplicity the results of this study were compared with Reverse Osmosis System Analysis (ROSA) software which was assumed to have acceptable marginal errors. Two different feed water (NaCl) concentrations 35,000mg/L and 38,000mg/L were investigated in this study. In this paper, the recovery rate, salt rejection, feed pressure and permeate concentration of each RO element in the pressure vessel was compared with ROSA as shown in figures 2 to 5. The results from this study showed a very good agreement with ROSA up to 95%. Most of the previous studies were focused on studying the performance of a single RO membrane. This study, probably, the first to present a systematic procedure for estimating the performance of multiple RO elements in a pressure vessel.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.