Abstract

The dose error determined on the basis of recommendations for calculating the shielding of electron accelerators is determined by comparing the photon dose distribution calculated by the Monte Carlo method in concrete, iron, and lead from isotropic monoenergetic sources and sources with the bremsstrahlung spectrum of electron accelerators with energy above 15 MeV. It is shown that the highest error in using the mono-energetic sources to simulate sources of bremsstrahlung is observed for concrete protection and the smallest error is observed for lead. Suggestions are formulated for reducing the errors by means of individual selection of the effective energy of an equivalent monoenergetic source as a function of the energy of the accelerator electrons and the employed material.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.