Abstract
There is a need for the development of finite element (FE) models based on medical datasets, such as magnetic resonance imaging and computerized tomography in computation biomechanics. Direct conversion of graphic voxels to FE elements is a commonly used method for the generation of FE models. However, conventional voxel-based methods tend to produce models with jagged surfaces. This is a consequence of the inherent characteristics of voxel elements; such a model is unable to capture the geometries of anatomical structures satisfactorily. We have developed a robust technique for the automatic generation of voxel-based patient-specific FE models. Our approach features a novel tetrahedronization scheme that incorporates marching-cubes surface smoothing together with a smooth-distortion factor (SDF). The models conform to the actual geometries of anatomical structures of a lumbar spine segment (L3). The resultant finite element analysis (FEA) at the surfaces is more accurate compared to the use of conventional voxel-based generated FE models. In general, models produced by our method were superior compared to that obtained using the commercial software ScanFE.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.