Abstract
Capturing daylight into an unevenly lit lecture room with north-facing windows has been analyzed with the help of Photopia and Radiance. Two different daylighting systems, a light tube and a fiber-optic solar dish concentrator, are considered as means to lead light rays into an interior space with insufficient illumination from daylight. Photopia is used to photometrically model the daylighting systems as light travels through highly reflective light guiding elements of these systems. The candela power distribution curves (CDCs) generated by Photopia are imported by Radiance to produce photometric data and images of different locations in the lecture room. These results clearly reveal the functional benefits of each system when harvesting daylight for indoor illumination. For solar altitudes of less than 50°, more daylight can be harvested by the solar tracking dish concentrator system. Also, its minimum-to-average (illuminance) uniformity ratio on the work plane remains between 0.55 and 0.72, varying quite less than that of the light tube, ranging from 0.46 to 0.88.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.