Abstract

The JSI TRIGA Mark II, IJS research reactor is equipped with numerous irradiation positions, where samples can be irradiated by neutrons and γ-rays. Irradiation position selection is based on its properties, such as physical size and accessibility, as well as neutron and γ-ray spectra, flux and dose intensities. This paper presents an overview on the neutron and γ-ray fluxes, spectra and dose intensities calculations using Monte Carlo MCNP software and ENDF/B-VII.0 nuclear data libraries.The dose-rates are presented in terms of ambient dose equivalents, air kerma, and silicon dose equivalent. At full reactor power the neutron ambient dose equivalent ranges from 5.5×103Svh−1 to 6×106Svh−1, silicon dose equivalent from 6×102Gy/hsi to 3×105Gy/hsi, and neutron air kerma from 4.3×103Gyh−1 to 2×105Gyh−1. Ratio of fast (1MeV<E) vs. thermal neutrons (E<0.625eV) ranges from 1.5 to 8.4×10−2,γ ray ambient dose equivalent at full reactor power from 3.4×103Svh−1 to 3.6×105Svh−1 and γ air kerma range 3.1×103Gyh−1 to 2.9×105Gyh−1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.