Abstract

Important kinetic parameters such as effective multiplication factor, keff, excess reactivity, neutron flux and power distribution, and power peaking factors of TRIGA Mark II research reactor in Bangladesh have been calculated using the comprehensive neutronics calculation code system SRAC 2006 with the evaluated nuclear data libraries ENDF/B-VII.0 and JENDL-3.3. In the code system, PIJ code was employed to obtain cross section of the core cells, followed by the integral calculation of neutronic parameters of the reactor conducted by CITATION code. All the analyses were performed using the 7-group macroscopic cross section library. Results were compared to the experimental data, the safety analysis report (SAR) of the reactor provided by General Atomic as well as to the simulated values by numerically benchmarked MCNP4C, WIMS-CITATION and SRAC-CITATION codes. The maximum power densities at the hot spot were found to be 169.7W/cc and 170.1W/cc for data libraries ENDF/B-VII.0 and JENDL-3.3, respectively. Similarly, the total peaking factors based on ENDF/B-VII.0 and JENDL-3.3 were calculated as 5.68 and 5.70, respectively, which were compared to the original SAR value of 5.63, as well as to MCNP4C, WIMS-CITATION and SRAC-CITATION results. It was found in most cases that the calculated results demonstrate a good agreement with our experiments and published works. Therefore, this analysis benchmarks the code system and will be helpful to enhance further neutronics and thermal hydraulics study of the reactor.