Abstract

Understanding the behaviour of retaining walls subjected to earth pressures is an interesting but a complex phenomenon. Though a vast amount of literature is available in this study area, a majority of the literature, either theoretical or experimental, address the problem of a vertical retaining wall with a horizontal backfill. Therefore, it is decided to develop a limit equilibrium based protocol for the evaluation of passive earth pressure coefficients, K pγ for a vertical retaining wall resting against the inclined cohesionless backfill. The complete log spiral failure mechanism is considered in the proposed analysis. Though the limit equilibrium method is employed in the present investigation, an attempt is made to minimise the number of assumptions involved in the analysis. The passive earth pressure coefficients are evaluated and presented for the different combinations of soil frictional angle ϕ, wall frictional angle δ and sloping backfill angle i. The solutions obtained from the proposed research work are very close to the best upper bound solutions given in the literature by Soubra and Macuh (P I CIVIL ENG-GEOTEC 155:119-131, 2002) for the K pγ coefficients. A comparison of the proposed K pγ values is also made with the other available theoretical as well as experimental results and presented herein. As the method developed herein is capable of yielding the best possible upper bound solution and being simple to implement, it could be considered as one of the alternatives for the evaluation of passive earth pressure coefficients for a vertical retaining wall resting against the inclined cohesionless backfill.

Highlights

  • Understanding the behaviour of retaining walls subjected to earth pressures is an interesting but a complex phenomenon

  • In order to check the validity of the proposed results, a comparison is made with the other available theoretical as well as experimental investigations and the same is discussed in detail through the subsequent paragraphs

  • 45 25.07 58.47 85.25 119.46 202.57 45 35.64 84.76 123.39 171.82 315.14 proposed results fall well within the lower and upper bounds of limit analysis; and it can be inferred that, for the case of a vertical retaining wall resting against the horizontal cohesionless backfill and for all the combinations of φ and δ/φ values as reported in Table 3, the passive earth pressure coefficients obtained in this study are very close to the true solutions

Read more

Summary

Results

The passive earth pressure coefficients are evaluated and presented for the different combinations of soil frictional angle φ, wall frictional angle δ and sloping backfill angle i. The solutions obtained from the proposed research work are very close to the best upper bound solutions given in the literature by Soubra and Macuh (P I CIVIL ENG-GEOTEC 155:119-131, 2002) for the Kpγ coefficients. A comparison of the proposed Kpγ values is made with the other available theoretical as well as experimental results and presented

Conclusion
Introduction
Results and discussion
Conclusions

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.