Abstract

We are developing an Electron-Tracking Compton imaging Camera (ETCC) based on a gaseous Time Projection Chamber (TPC) and a scintillation camera. The ETCC detects the energy and the direction of the incident gamma ray using the information of the recoil electron and the scattered gamma ray. We have developed the ETCC with a detection volume of 23 × 28 × 30 cm3 which consists of the 23 × 28 × 30 cm3 gaseous TPC and 30 × 30 cm2 GSO(Ce) scintillation camera. And we obtained the gamma-ray image and investigated the performances of the ETCC. The Angular Resolution Measure (ARM) and the Scatter Plane Deviation (SPD) are 6.1 degree and 64.5 degree (HWHM) at 662keV, respectively, and the energy resolution is 18.0%(FWHM) at 662keV.