Abstract

Due to the significant role of rotational properties for normal knee function, this study aimed to investigate transverse plane kinematics and kinetics in total knee arthroplasty and unicondylar knee arthroplasty patients during activities of daily living compared to a healthy control group, including stair ascent and descent. The study participants consisted of a total knee arthroplasty group including posterior cruciate retaining and posterior stabilized designs as well as a unicondylar knee arthroplasty group and a healthy control group. Three-dimensional kinematics and kinetics were captured using a Vicon system and two Kistler force plates embedded in the floor and another two in a staircase. Inverse dynamics of the lower limbs was computed in Anybody™ Modeling System. Transverse plane joint angles and joint moments were analyzed utilizing the statistical non-parametric mapping approach, considering the entire curve shape for statistical analysis. The patients with total knee arthroplasty exhibited significantly reduced knee internal rotation of the operated knee compared to the control group and the patients’ unimpaired limb, especially during the stair climbing tasks. Both unicondylar and total knee arthroplasty patients were found to have similar reduced internal rotation motion time series in stair descent. In conclusion, potential kinematic and kinetic benefits of unicondylar knee arthroplasty over total knee arthroplasty could not be proven in the current study. Aside from the usually mentioned reasons inducing constrained knee internal rotation in total knee arthroplasty patients, future studies should investigate to what extent co-contraction may contribute to this functional impairment in patients after knee arthroplasty surgery.

Highlights

  • Three-dimensional motion analysis enables examiners to grasp pathologic joint kinematics and kinetics in patients before and after knee arthroplasty (KA) surgery

  • The total knee arthroplasty (TKA) and the unicondylar knee arthroplasty (UKA) subjects had an 18% and 16% higher body mass accompanied by 14% greater body mass index (BMI) values in comparison to the control group (CG) (CG vs TKA: p = 0.0062, CG vs UKA: p = 0.0037, TKA vs UKA: p = 0.9704)

  • Foot contact time during stair negotiation significantly increased for both KA groups (by 9% in the TKA-group (p = 0.016) and 18% in the UKA group (p = 0.017))

Read more

Summary

Introduction

Three-dimensional motion analysis enables examiners to grasp pathologic joint kinematics and kinetics in patients before and after knee arthroplasty (KA) surgery. The graduate college of the German Sport University funded the PhD studies for the corresponding author IK in the form of salary (URL:http://www.dshskoeln.de/visitenkarte/ einrichtung/graduiertenkolleg-mechanobiologie/). (English: “Science and Advanced Training Society in the field of orthopedics”) funded the knee arthroplasty subject’s accommodation and travel costs to Cologne The German Knee Society supported the study in form of grant (URL: http://deutsche-kniegesellschaft.de/ en/). The funder did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript

Objectives
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call