Abstract

Hydrogen recycle service has presented a special challenge for centrifugal compressors and particularly the casing seals, mainly because of contamination from process gas. This feature, reproduced with permission from the Turbomachinery Laboratory, reviews a simplified process to identify the sources of contaminants affecting both dry and wet seals. It lists precautions for the application of dry seals in this service, and discusses improvements to materials used for a wet seal design. Finally, it highlights two case histories where retrofits with the improved liquid film seal have significantly reduced sour seal oil leakage rates.