Abstract

This paper presents experimental studies on the compressive behavior of a sustainable steel-fiber reinforced composite bar (SFCB) under uniaxial compressive loading. The SFCB, combined with steel and fiber reinforced polymer (FRP), is expected to significantly enhance structural safety and sustainability. A new test method with LVDT and extensometer sensors was developed and verified through experiments to test the tensile and compressive behavior of the SFCB. Fifty-four specimens including SFCB and inner steel bar (ISB) with different slenderness ratios were tested. The test results indicated that the initial compressive elastic modulus of the SFCB was essentially the same as its initial tensile elastic modulus. The compressive yield load of the SFCB was essentially irrelevant to the slenderness ratio, and the ultimate compressive stress of the SFCBs varied inversely with the slenderness ratios. The squash load of the SFCB tended to be conservative for predicting the compressive yield load of the SFCB, while the equivalent critical global buckling load of the SFCB was much higher than its corresponding compressive yield load and ultimate load due to the inelastic buckling mechanism of the SFCB within the range of the equivalent slenderness ratios studied in this paper.

Highlights

  • During earthquakes, the longitudinal reinforcing bars of concrete members may experience significant lateral deformation initiated by spalling of the concrete cover due to inferior factors such as harsh environments, improper construction practices, and natural hazards

  • The applicability of FRP bars has been restricted by the amount of inferior factors such as significant discreteness [17], insufficient shear capacity, low elastic modulus (for glass-fiber reinforced polymer (GFRP) bars and basalt-fiber reinforced polymer (BFRP) bars [18,19]), relatively lower compressive strength compared to tensile strength [20], and last but not least, poor ductility, which would potentially lead to a dangerous brittle failure mode in the FRP reinforced concrete structures

  • This paper presents the experimental studies on the compressive properties of a sustainable steel-fiber reinforced composite bar (SFCB) under uniaxial compression loading

Read more

Summary

Introduction

The longitudinal reinforcing bars of concrete members may experience significant lateral deformation initiated by spalling of the concrete cover due to inferior factors such as harsh environments, improper construction practices, and natural hazards. This oversized lateral deformation of the longitudinal reinforcements reduces the response ductility of the concrete members, which cannot be evaluated precisely using analytical models that neglect inelastic material mechanisms [1]. The slenderness ratio, initial eccentricity ratio, and tensile property are commonly regarded as the three primary factors affecting the compressive properties such as the buckling strength and post-buckling behavior of reinforcing bars. The compressive behavior of the SFCBs as well as their major mechanical properties were comprehensively studied and statistically analyzed

Equivalent Flexural Stiffness Principle of the SFCB
Loading Program
Uniaxial Tensile Properties of the SFCB
Test Results
Initial Compressive Elastic Modulus
Compressive Post-Yield Modulus
Compressive Yield Load and Stress
Ultimate Compressive Load and Stress
Conclusions

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.