Abstract
This paper describes a series of compression tests conducted on cold-formed simple lipped channels and lipped channels with intermediate stiffeners in the flanges and web fabricated from high strength steel plate of thickness 0.6 and 0.8 mm with the nominal yield stress 560 MPa. A range of lengths of lipped channel sections were tested to failure with both ends of the column fixed with a special capping to prevent local failure of column ends and influence from the shift of centroid during testing. The high strength cold-formed steel channel sections of intermediate lengths generally displayed a significant interaction between local and distortional buckling. A noticeable interaction between local and overall buckling was also observed for the long columns. A significant post-buckling strength reserve was shown for those sections that showed interaction between local and distortional or overall buckling. Simple design strength formulas in the Direct Strength Method for the thin-walled cold-formed steel sections failing in the mixed mode of local and distortional buckling have been studied. The strengths predicted by the strength formulas proposed are compared with the test results for verification.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.