Abstract

Slight non-parallelism of the gratings in the compressor of a chirped-pulse amplification laser system produces angular chirp which results in a significant reduction of the focused intensity due to elongation of the pulse duration and enlargement of the focal spot. The effect of three-dimensional relative misalignment angles between two gratings on the far-field pattern of the pulses propagating through them is investigated by ray tracing. The far-field pattern provides two-dimensional information of the uncompensated angular dispersion directly. A simple and intuitive alignment procedure to achieve parallelism of the compression gratings by far-field monitoring is demonstrated experimentally, while the alignment precision is found to be the same as the methods proposed previously.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.