Abstract

BackgroundSmall animal models of human diseases are an indispensable aspect of pre-clinical research. Being dynamic, most pathologies demand extensive longitudinal monitoring to understand disease mechanisms, drug efficacy and side effects. These considerations often demand the concomitant development of monitoring systems with sufficient temporal and spatial resolution.Methodology and ResultsThis study attempts to configure and optimize a clinical 3 Tesla magnetic resonance scanner to facilitate imaging of small animal central nervous system pathologies. The hardware of the scanner was complemented by a custom-built, 4-channel phased array coil system. Extensive modification of standard sequence protocols was carried out based on tissue relaxometric calculations. Proton density differences between the gray and white matter of the rodent spinal cord along with transverse relaxation due to magnetic susceptibility differences at the cortex and striatum of both rats and mice demonstrated statistically significant differences. The employed parallel imaging reconstruction algorithms had distinct properties dependent on the sequence type and in the presence of the contrast agent. The attempt to morphologically phenotype a normal healthy rat brain in multiple planes delineated a number of anatomical regions, and all the clinically relevant sequels following acute cerebral ischemia could be adequately characterized. Changes in blood-brain-barrier permeability following ischemia-reperfusion were also apparent at a later time. Typical characteristics of intra-cerebral haemorrhage at acute and chronic stages were also visualized up to one month. Two models of rodent spinal cord injury were adequately characterized and closely mimicked the results of histological studies. In the employed rodent animal handling system a mouse model of glioblastoma was also studied with unequivocal results.ConclusionsThe implemented customizations including extensive sequence protocol modifications resulted in images of high diagnostic quality. These results prove that lack of dedicated animal scanners shouldn't discourage conventional small animal imaging studies.

Highlights

  • Small animal models of human pathologies involving rats and mice are principal to further our understanding of various disease processes

  • The implemented customizations including extensive sequence protocol modifications resulted in images of high diagnostic quality

  • These results prove that lack of dedicated animal scanners shouldn’t discourage conventional small animal imaging studies

Read more

Summary

Introduction

Small animal models of human pathologies involving rats and mice are principal to further our understanding of various disease processes. They are invaluable in the pre-clinical evaluation of potential drug candidates for their therapeutic efficacy and/or toxicity profiles. Pathologic states being dynamic in nature makes it mandatory to monitor them in a longitudinal fashion This necessitates the use of reliable non-invasive monitoring techniques, which, should satisfy a minimal set of criteria like, 1) adequate spatial resolution and signal-to-noise ratio (SNR), 2) ability to morphologically differentiate tissues with required contrast, along with 3) a good temporal resolution[1]. Most pathologies demand extensive longitudinal monitoring to understand disease mechanisms, drug efficacy and side effects These considerations often demand the concomitant development of monitoring systems with sufficient temporal and spatial resolution

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call