Abstract
The catheterization laboratory predisposes to occupational health hazards. Chronic radiation exposure (RE) direct injuries include a predilection to cataracts and concerns for cancers. Indirectly adverse effects underly the prevalence of orthopedic maladies in interventionists, linked to the burden of mandatory protective lead aprons. A novel comprehensive shielding system (Protego, Image Diagnostics Inc) has been validated in early studies to provide excellent radiation protection. The system is designed to reduce operator RE sufficient to eliminate the need for personal lead aprons. Recent system refinements offer potentially even greater degrees of protection. This clinical study evaluated the efficacy of this system. This single-center 2-group cohort study compared physician operator RE utilizing the latest iteration of the Protego shield (n = 25 cases) or standard protection (personal leaded apparel and drop-down shield, n = 25 cases) during routine cardiac catheterization procedures. RE at both thyroid and waist levels were measured with a real-time dosimetry system (Raysafe) and calculated on a mean per case basis at both thyroid and waist levels. Additional parameters collected included procedure type, access site, per case fluoroscopy time, and patient factors including body mass index. Between-group comparisons were conducted to evaluate RE by group and measurement sites. Protection with Protego was superior to standard methods. Protego showed markedly lower RE at both the thyroid level (0.36 ± 0.86 vs 58.5 ± 50.2 μSv; P < .001) and the waist level (0.84 ± 2.99 vs 121.4 ± 171.2 μSv; P < .001. "Zero" total RE was documented in 68% (n = 17) of Protego cases; in contrast, standard protection did not achieve "zero" exposure in a single case. The Protego shield system provides excellent RE protection to the physician operator, achieving "zero" RE in two-thirds of cases. RE was superior to standard protection methods. The magnitude of protection achieves state regulatory standards sufficient to allow operators to perform procedures without orthopedically burdensome lead aprons. This shield system has the potential to reduce occupational health hazards.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Society for Cardiovascular Angiography & Interventions
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.