Abstract

Abstract In this paper, the performance of R744 and R744/R170 mixed refrigerants in refrigeration and air source heat pump systems is studied by the simulation method. The change trend of coefficient of performance (COP), refrigeration/heat capacity, power consumption with discharge pressure, and the ratio of R744 is analyzed. In addition, optimal parameters of the system are discussed in detail with the change of evaporation temperature, outlet temperature of the gas cooler, and different proportions of R744. The results show that when the discharge pressure is 8–12 MPa, there is a critical ratio of R744. When the ratio of R744 is less than the critical ratio, the optimal pressure of the system increases with the increase of the ratio of R744, and when the ratio of R744 is higher than critical ratio, the optimal pressure of the system decreases with the increase of the ratio of R744. The change trend of COP with the ratio of R744 is first decreasing and then increasing, the optimal discharge temperature of the system increases with the increase of the ratio of R744, and the change trend of optimal discharge pressure with the ratio of R744 is first increasing and then decreasing. In addition, when the evaporation temperature is 233–253 K and the gas cooler outlet temperature is 308–318 K, the average optimal pressure and temperature of R744/R170 (25/75) are 11.64% and 8.06% lower than R744, respectively. And it is the most suitable refrigerant to replace R744. Finally, the optimal performance parameter correlations of R744, R744/R170 (25/75), R744/R170 (50/50), and R744/R170 (77.6/22.4) under the given conditions are fitted through the simulation data.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call